The LG LSXS26326S is a 26 cubic foot French Door Refrigerator with external water and ice dispenser, linear compressor technology, Smart Cooling Plus™ system, Door Cooling+™, and Smart Diagnosis™ capability. This service manual provides authorized technicians with essential information for installation, maintenance, troubleshooting, and repair. Below are key sections covering safety, specifications, component location, disassembly, diagnostics, and parts information.
Before servicing, disconnect power and review all warnings.
| Hazard | Precaution |
|---|---|
| Electrical Shock | Unplug unit or disconnect circuit breaker before accessing internal components. |
| Refrigerant | Use proper recovery equipment. Avoid open flames. R-600a is flammable. |
| Sharp Edges | Wear cut-resistant gloves when handling evaporator coils or sheet metal. |
| Heavy Components | Use assistance when lifting compressor or sliding out unit. |
| Water Leaks | Ensure water line is shut off before disconnecting dispenser system. |
Key internal components: Main PCB, Inverter PCB, Compressor, Evaporator Fan, Condenser Fan, Defrost Heater, Temperature Sensors, Water Inlet Valve, Ice Maker Assembly.
WARNING! Label all wires and connectors before disassembly.
Step-by-step guide for common service tasks.
CAUTION! Handle door gaskets carefully to avoid tears.
Use multimeter to test continuity, voltage, and resistance.
| Component | Test Point | Expected Value |
|---|---|---|
| Compressor Windings | Between terminals (C-S, C-R, S-R) | Resistance: 5-20Ω (varies by temp) |
| Defrost Heater | Across heater terminals | Continuity (~20-40Ω) |
| Evaporator Fan Motor | Across motor terminals | Continuity (~100-300Ω) |
| Thermistor (Fridge) | Resistance at 77°F (25°C) | ~10kΩ |
| Water Inlet Valve | Solenoid coil resistance | ~200-500Ω |
Linear compressor, capillary tube, evaporator, condenser. Charging: R-600a, 2.0 oz ± 0.1 oz.
WARNING! R-600a is flammable. No brazing on pressurized system.
Touch panel with temperature settings, filter reset, ice maker control, and diagnostic mode entry.
Diagnostic Mode Entry: Press and hold "Ice Type" and "Light" buttons simultaneously for 3 seconds. Use arrows to scroll through test modes.
Test Functions: Compressor relay test, fan motor test, defrost heater test, sensor values display.
Components: Water inlet valve, filter, ice maker assembly, water dispenser solenoid, water tank.
| Error Code | Description | Probable Cause |
|---|---|---|
| FF / EF | Freezer Fan Error | Fan motor failure, obstruction, wiring. |
| RF / RE | Refrigerator Fan Error | Fan motor failure, obstruction, wiring. |
| dH / dF | Defrost Heater Error | Heater open, thermistor, defrost sensor. |
| IE / IC | Ice Maker Communication Error | Wiring harness, connector, ice maker PCB. |
| tS / tE | Temperature Sensor Error | Open/short in fridge or freezer sensor. |
Clear Codes: Enter diagnostic mode and select "Error Clear" or disconnect power for 10 minutes.
Refer to official LG parts catalog for part numbers. Key replacement parts:
Note: Always verify part number against model and serial number.
Under normal ambient conditions (70°F), after 24 hours of operation:
| Parameter | Expected Range |
|---|---|
| Refrigerator Compartment Temp | 36°F - 38°F |
| Freezer Compartment Temp | -2°F to 2°F |
| Compressor Run Current | 0.8A - 1.2A |
| Compressor Casing Temperature | 130°F - 180°F |
| Condenser Outlet Temperature | 90°F - 120°F |
| Evaporator Inlet/Outlet ΔT | 10°F - 15°F |
Service Support: LG Service Network: 1-800-243-0000. Website: www.lg.com.