The LG Refrigerator LRSC26925TT is a 26 cubic foot French Door refrigerator with a bottom freezer, featuring LG's LinearCompressor™ technology, Smart Cooling Plus™ system, Door Cooling+™, Craft Ice™ maker, and InstaView™ Door-in-Door. This manual provides essential information for troubleshooting, maintenance, and repair procedures for qualified technicians. Below are key sections covering safety, diagnostics, component replacement, and specifications.
Before performing any repair, disconnect the refrigerator from the electrical power source. Use appropriate personal protective equipment (PPE).
| Hazard | Precaution |
|---|---|
| Electrical Shock | Unplug unit or disconnect circuit breaker before servicing. |
| Refrigerant | Only EPA-certified technicians may handle refrigerant. Use recovery equipment. |
| Sharp Edges | Wear cut-resistant gloves when handling evaporator coils or sheet metal. |
| Heavy Components | Use proper lifting techniques or assistance for compressors and condensers. |
| Flammable Materials | Keep open flames and sparks away during brazing or electrical work. |
Enter diagnostic mode by pressing and holding the "Ice Type" and "Light" buttons on the control panel for 3 seconds. Use the Temp buttons to navigate.
| Code | Description | Possible Cause |
|---|---|---|
| FF | Freezer Fan Motor Error | Obstruction, faulty fan motor, wiring |
| RF | Refrigerator Fan Motor Error | Blocked vent, failed fan, connector issue |
| dH | Defrost Heater Error | Open heater, defrost sensor, thermostat |
| PS | Power Surge/Supply Issue | Voltage fluctuation, main PCB |
| CE | Communication Error | Wiring harness, display board, main control |
Note: Clear codes after repair by unplugging unit for 1 minute.
LinearCompressor™ Test: Disconnect leads, check resistance between terminals (typical 10-20 Ω). Listen for abnormal noise.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Not cooling | Compressor not running, blocked vents, low refrigerant | Check power, test compressor, ensure fan operation, verify refrigerant charge. |
| Excessive frost in freezer | Defrost system failure, door seal leak | Test defrost heater, thermostat, and sensor. Inspect and replace door gasket if torn. |
| Ice maker not working | Water supply issue, clogged filter, faulty valve | Check water line pressure, replace filter (every 6 months), test water inlet valve solenoid. |
| Unusual noise | Fan obstruction, compressor mount loose, tubing vibration | Inspect evaporator/condenser fans, tighten compressor mounts, secure refrigerant lines. |
| Display blank/error | Power issue, control board failure | Verify outlet power, test/replace main or display PCB. |
Refer to schematic diagram on page 12 of the physical manual. Key connections:
Warning: Always verify diagram revision matches your model's serial number range.
Common replacement parts for LRSC26925TT:
Refer to Exploded View Diagram EV-27 for disassembly sequence and part locations.
Final Check: Confirm no water leaks, unusual noises, or error codes.
This appliance complies with FCC Part 15, Subpart B. The LinearCompressor™ carries a 10-year limited warranty (parts and labor, registration required). Other parts: 1-year full, 2-5 years limited (sealed system). For warranty service, contact LG at 1-800-243-0000 or visit www.lg.com. Use only genuine LG replacement parts.
Disposal: Dispose of in accordance with local regulations for appliances containing refrigerant and blowing agents.