The LG Refrigerator LMXS30776S is a 30 cubic foot French Door refrigerator with InstaView Door-in-Door, Craft Ice™ maker, Smart Cooling Plus™ system, linear compressor, and Wi-Fi connectivity. This service manual provides authorized technicians with detailed information for installation, diagnosis, repair, and maintenance. Below are key sections covering safety, specifications, component locations, disassembly, troubleshooting, and parts lists.
Before servicing, read all safety warnings. Disconnect power before accessing electrical components.
| Hazard | Precaution |
|---|---|
| Electrical Shock | Unplug unit or disconnect circuit breaker. Verify with voltmeter. |
| Refrigerant | Use certified recovery equipment. Avoid open flames. |
| Sharp Edges | Wear cut-resistant gloves when handling panels and shelves. |
| Heavy Components | Use proper lifting techniques; two-person lift for compressor. |
| Chemical Exposure | Wear safety glasses and gloves when handling refrigerants or cleaning agents. |
Main components: Control board, linear compressor, evaporator fan, condenser fan, damper assembly, ice maker assembly, water valve, temperature sensors.
WARNING! Refer to diagrams before disassembly to avoid damage to wire harnesses.
Proper installation ensures optimal performance and warranty compliance.
CAUTION! Do not install near heat sources. Ensure water line is leak-free.
Step-by-step guide for accessing key components.
To Access Main Control Board:
To Access Evaporator:
Tip: Take photos during disassembly for reference during reassembly.
Circuit diagrams and voltage specifications for major components.
| Component | Test Point | Expected Value |
|---|---|---|
| Main Control Board Input | L1 to N | 115 VAC ±10% |
| Compressor Terminals | Between P1-P2 | 80-160 VAC (varies with load) |
| Evaporator Fan Motor | Red to White wire | 12 VDC |
| Damper Motor | Connector pins 1-2 | 5 VDC (pulsed) |
| Ice Maker Assembly | Harness connector | 120 VAC when calling for ice |
WARNING! Always disconnect power before performing continuity or resistance checks.
Sealed system using R-600a refrigerant. Service requires EPA 608 Type II certification.
CAUTION! R-600a is flammable. No brazing on sealed system without proper purging.
The main control board monitors sensors and controls all functions. Access diagnostic mode.
Entering Diagnostic Mode:
Key Tests: Compressor Relay, Fan Test, Defrost Heater, Valve Test, Sensor Readouts.
| Error Code | Description | Possible Cause | Corrective Action |
|---|---|---|---|
| FF / EF | Freezer Fan Fault | Obstructed fan, bad motor, wiring | Check for ice blockage, test fan motor resistance (50-200 Ω). |
| PF | Power Failure | Power interruption > 2 hours | Reset by cycling power. Check outlet. |
| dH / CH | Door Open Alert | Door not fully closed | Check door alignment, gasket, hinge. |
| IE / ICE | Ice Maker Fault | Jam, low water pressure, faulty fill cup | Clear ice jam, check water pressure (20-120 psi). |
| LE / LF | Linear Compressor Fault | Overload, start failure, board fault | Check compressor windings (P1-C: 10Ω, P2-C: 20Ω). |
Key replacement parts for model LMXS30776S.
Note: Always verify part number with serial number of unit before ordering.
Expected operating parameters under normal ambient conditions (70°F).
| Parameter | Refrigerator Compartment | Freezer Compartment |
|---|---|---|
| Set Point | 37°F | 0°F |
| Actual Temp Range | 34°F - 40°F | -2°F to +5°F |
| Compressor Run Time | 40-60% duty cycle | |
| Evaporator Temp (During Cooling) | N/A | 10°F to 20°F |
| Condenser Discharge Air Temp | 90°F - 115°F above ambient | |
Reset to Factory Defaults: In diagnostic mode, select "INIT" option.
Service Support: LG Service Network: 1-800-243-0000. Tech Website: www.lgservice.com