The LG LRFC2606S is a 26 cubic foot French Door Refrigerator with dual ice makers, linear compressor, smart cooling technology, door cooling+, and smart diagnosis features. This repair manual provides detailed instructions for troubleshooting, disassembly, component testing, and reassembly for qualified service technicians. Below are key sections covering safety, diagnostics, parts replacement, and technical specifications.
Before servicing, disconnect power. Use proper tools and PPE.
| Hazard | Precaution |
|---|---|
| Electrical Shock | Unplug unit or disconnect circuit breaker before accessing internal components. |
| Refrigerant | Use certified recovery equipment. Avoid open flames. Ventilate area. |
| Sharp Edges | Wear cut-resistant gloves when handling evaporator coils or sheet metal. |
| Heavy Parts | Use assistance when lifting compressor or condenser assembly. |
| Capacitors | Discharge run capacitors with a 20k ohm resistor before handling. |
Model: LRFC2606S. Type: French Door Refrigerator with Bottom Freezer.
Enter diagnostic mode by pressing and holding "Ice Type" and "Light" buttons on control panel for 3 seconds.
WARNING! Interpret codes using official LG code chart. Do not reset until fault is corrected.
General sequence: Remove external panels, access internal components.
CAUTION! Label all wires and connectors. Keep screws organized.
Use multimeter for continuity and resistance checks.
| Component | Test Procedure | Expected Value |
|---|---|---|
| Linear Compressor | Check resistance between terminals. Test for ground short. | Terminals: 5-15Ω. No continuity to ground. |
| Evaporator Fan Motor | Check resistance across motor leads. | 100-500Ω. Spin freely. |
| Defrost Heater | Check continuity. | 20-40Ω continuity. |
| Temperature Sensors (Thermistors) | Measure resistance at room temp (approx. 77°F/25°C). | 10kΩ ±5%. |
| Main Control Board | Check input voltage (115V AC) and output to components. | Refer to wiring diagram. |
Key replacement parts for LRFC2606S.
Note: Always verify part number with serial number before ordering.
After repair, reassemble in reverse order of disassembly.
Tip: Torque service valve caps to 12 ft-lbs. Do not overtighten.
Plug in unit and run performance tests.
WARNING! Allow 24 hours for temperatures to stabilize before final verification.
Refer to separate wiring diagram sheet (included in full manual). Diagram shows connections between main control board, compressor, fans, sensors, ice makers, and user interface.
Key Connectors: CN701 (Power Input), CN702 (Compressor), CN703 (Evaporator Fan), CN704 (Defrost Heater), CN705 (Fresh Food Ice Maker), CN706 (Freezer Ice Maker).
Exploded view diagrams illustrate the relationship and order of all parts for the cabinet, doors, and internal assemblies. Use for identifying part numbers and correct assembly sequence.
CAUTION! Handle glass shelves and door liners with care to avoid cracking.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Not cooling | Compressor not running, blocked vents, low refrigerant | Check power, test compressor, inspect evaporator for frost, check for restrictions. |
| Excessive frost in freezer | Defrost system failure, door seal leak | Test defrost heater, thermostat, and control board. Inspect and replace door gasket if damaged. |
| Ice maker not working | Water supply, faulty module, frozen fill tube | Check water valve, test ice maker motor, inspect for ice blockage in fill tube. |
| Unusual noise | Fan obstruction, compressor mount loose, rattling parts | Inspect evaporator and condenser fans. Tighten compressor mounts. Check for loose panels. |
| Error code displayed | Sensor failure, communication fault | Enter diagnostic mode. Replace faulty sensor or main PCB as indicated by code. |
Reset: Unplug for 5 minutes to reset control board.
Service Support: LG Service Website or authorized service center.